Skip to main content
Erschienen in: International Journal of Legal Medicine 1/2019

21.07.2018 | Original Article

Detectability of bloodstains after machine washing

verfasst von: Michaela Hofmann, Jiri Adamec, Katja Anslinger, Birgit Bayer, Matthias Graw, Oliver Peschel, Martin M. Schulz

Erschienen in: International Journal of Legal Medicine | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Bloodstains on textiles can provide useful information for the forensic reconstruction of a crime. Surprisingly, little is known about the applicability of bloodstain traces after a textile was machine washed. In this study, we investigated the effect of machine washing on bloodstains on both cotton and polyester cloths. The influence of the washing detergent, the type of washing machine, the washing temperature, and the duration of drying of the bloodstain prior to washing as well as the drying temperature was investigated. Additionally, the molecular analyses of a subsample of the experiments were conducted. We found that although the primary morphology of the traces is often blurred, the presence of blood on the textiles can still be detected in many cases. Blood can also be transmitted to previously blood-free textiles during the washing process, leading to a positive Luminol or Combur® reaction of these samples. When traces of blood can be detected via the Luminol reaction, a molecular identification of the blood donor was successful in 28% of the cases.
Anhänge
Nur mit Berechtigung zugänglich
Fußnoten
1
Messler and colleagues (1981) showed that the height of dropping has an effect on the appearance of bloodstains on textiles.
 
2
It was tried to spray the samples with the same amount of spray since Zweidinger et al. [17] found a correlation between brightness on photos and the amount of Luminol sprayed onto the sample.
 
Literatur
2.
Zurück zum Zitat Ramsthaler F, Peschel O, Rothschild M (eds) (2015) Forensische Blutspurenmusteranalyse. Lehmanns, Berlin Ramsthaler F, Peschel O, Rothschild M (eds) (2015) Forensische Blutspurenmusteranalyse. Lehmanns, Berlin
3.
Zurück zum Zitat Robertson JR, Roux C, Wiggins K (2002) Forensic examination of Fibres, Second edn. CRC Press, Boca Raton Robertson JR, Roux C, Wiggins K (2002) Forensic examination of Fibres, Second edn. CRC Press, Boca Raton
5.
Zurück zum Zitat Messler H, Berghaus G, Dotzauer G (1981) Der Einfluß textiltechnischer Größen eines Spurenträgers auf das Erscheinungsbild einer Blutspur. Kriminalistik Forensische Wiss 44:125–137 Messler H, Berghaus G, Dotzauer G (1981) Der Einfluß textiltechnischer Größen eines Spurenträgers auf das Erscheinungsbild einer Blutspur. Kriminalistik Forensische Wiss 44:125–137
6.
Zurück zum Zitat Messler H, Berghaus G, Dotzauer G (1982) Der Einfluss textiltechnischer Größen eines Spurenträgers auf die Aufnahmefähigkeit für Blut. Arch Kriminol 169:99–113PubMed Messler H, Berghaus G, Dotzauer G (1982) Der Einfluss textiltechnischer Größen eines Spurenträgers auf die Aufnahmefähigkeit für Blut. Arch Kriminol 169:99–113PubMed
7.
Zurück zum Zitat Rand S, Madea B, Brinkmann B (1985) Zur Morphologie von Blutspuren. Beitr Zur Gerichtl Med 43:259–264 Rand S, Madea B, Brinkmann B (1985) Zur Morphologie von Blutspuren. Beitr Zur Gerichtl Med 43:259–264
9.
Zurück zum Zitat Gifford WD (1999) Bloodstain survival in water. IABPA News 15:1–6 Gifford WD (1999) Bloodstain survival in water. IABPA News 15:1–6
10.
Zurück zum Zitat Adair T, Shaw R (2005) Enhancement of bloodstains on washed clothing using Luminol and LCV reagents. IABPA News 21:4–10 Adair T, Shaw R (2005) Enhancement of bloodstains on washed clothing using Luminol and LCV reagents. IABPA News 21:4–10
12.
Zurück zum Zitat Kamphausen T, Fandel SB, Gutmann JS, Bajanowski T, Poetsch M (2015) Everything clean? Transfer of DNA traces between textiles in the washtub. Int J Legal Med 129(4):709–714CrossRefPubMed Kamphausen T, Fandel SB, Gutmann JS, Bajanowski T, Poetsch M (2015) Everything clean? Transfer of DNA traces between textiles in the washtub. Int J Legal Med 129(4):709–714CrossRefPubMed
13.
Zurück zum Zitat Noël S, Lagacé K, Rogic A, Granger D, Bourgoin S, Jolicoeur C, Séguin D (2016) DNA transfer during laundering may yield complete genetic profiles. Forensic Sci Int Genet 23:240–247CrossRefPubMed Noël S, Lagacé K, Rogic A, Granger D, Bourgoin S, Jolicoeur C, Séguin D (2016) DNA transfer during laundering may yield complete genetic profiles. Forensic Sci Int Genet 23:240–247CrossRefPubMed
14.
Zurück zum Zitat Voskoboinik L, Amiel M, Reshef A, Gafny R, Barash M (2017) Laundry in a washing machine as a mediator of secondary and tertiary DNA transfer. Int J Legal Med:1–6 Voskoboinik L, Amiel M, Reshef A, Gafny R, Barash M (2017) Laundry in a washing machine as a mediator of secondary and tertiary DNA transfer. Int J Legal Med:1–6
15.
Zurück zum Zitat Weber K (1966) Die Anwendung der Chemiluminescenz des Luminols in der gerichtlichen Medizin und Toxikologie. Dtsch Z Für Gesamte Gerichtl Med 57:410–423 Weber K (1966) Die Anwendung der Chemiluminescenz des Luminols in der gerichtlichen Medizin und Toxikologie. Dtsch Z Für Gesamte Gerichtl Med 57:410–423
17.
Zurück zum Zitat Zweidinger RA, Lytle LT, Pitt CG (1973) Photography of bloodstains visualized by Luminol. J Forensic Sci 18:296–302CrossRefPubMed Zweidinger RA, Lytle LT, Pitt CG (1973) Photography of bloodstains visualized by Luminol. J Forensic Sci 18:296–302CrossRefPubMed
18.
Zurück zum Zitat Schulz MM, Brune V, Maierthaler M, Graw M (2011) Visualization of latent biological traces via 5-methylthioninhydrin (5-MTN) staining for forensic DNA typing. Forensic Sci Int Genet suppl series 3:530–531CrossRef Schulz MM, Brune V, Maierthaler M, Graw M (2011) Visualization of latent biological traces via 5-methylthioninhydrin (5-MTN) staining for forensic DNA typing. Forensic Sci Int Genet suppl series 3:530–531CrossRef
19.
Zurück zum Zitat Nilsson A (2006) The forensic Luminol test for blood: unwanted interference and the effect on subsequent analysis. Linköping University: faculty of health science Nilsson A (2006) The forensic Luminol test for blood: unwanted interference and the effect on subsequent analysis. Linköping University: faculty of health science
Metadaten
Titel
Detectability of bloodstains after machine washing
verfasst von
Michaela Hofmann
Jiri Adamec
Katja Anslinger
Birgit Bayer
Matthias Graw
Oliver Peschel
Martin M. Schulz
Publikationsdatum
21.07.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Legal Medicine / Ausgabe 1/2019
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-018-1897-2

Weitere Artikel der Ausgabe 1/2019

International Journal of Legal Medicine 1/2019 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin

Assistierter Suizid durch Infusion von Thiopental

Thiopental Originalie

Als Folge des Urteils des Bundesverfassungsgerichts zur Sterbehilfe im Jahr 2020 wurde in den Jahren 2021–2023 eine Reihe (n = 23) von assistierten Suiziden im Landesinstitut für gerichtliche und soziale Medizin Berlin mit jeweils identischen …

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …